0310_Toward a combined system of forward osmosis and reverse osmosis for seawater...

 

 

1. Title & Journal

 

Toward a combined system of forward osmosis and reverse osmosis for seawater desalination

 

2. Background of author

 

Yong-Jun Choia,d, June-Seok Choia, Hyun-Je Oha, Sangho Leea,*, Dae Ryook Yangb, Joon Ha Kimc

 

a. Korea Institute of Construction Technology, Gyeonggi-Do, 411-712, Korea Tel. +82-31-910-0320; Fax: +82-31-910-0291; email: s-lee@kict.re.kr

b. Department of Chemical & Biological Engineering, Korea University, Seoul, 136-701, Korea

c. Department of Environmental Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, 500-712, Korea

d. University of Science and Technology, 113 Gwahangno, Yuseong-gu, Daejeon, Korea

 

3. Summary

 본 논문은 simple film theory model을 이용한 시뮬레이션과 실험실 규모의 실험을 통하여 여러가진 조건에 대하여 정삼투 공정과 정삼투-역삼투 혼합공정을 연구하였다. 실험은 RO FO 공정 모두에서 쓰이는 상업용 멤브레인(SW30)을 사용하였으며, 병류흐름으로 진행하였다. 또한 공급용액으로는 증류수를, 유도용액으로는 NaCl 용액을 사용하였다. 실험적 결과 다음과 같은 결과를 내었다.

1)     FO모드에서의 직교류 정삼투 공정 실험결과와 시뮬레이션 한 결과는 거의 일치하였다.

2)     유도용액의 농도가 증가할수록, 공급용액의 속도가 높아질수록 flux는 높아진다. 시뮬레이션한 결과와 실험 결과가 거의 유사하다.

-       유도용액의 농도가 증가하면 삼투압차가 커지므로 flux가 높아짐

-       공급용액의 속도가 높아지면 농도분극 현상이 줄어들기 때문에 flux가 높아짐

3)     FO-RO 혼합공정에서의 flux가 어떤 특정한 조건에서 FO, RO 단독공정에서의 flux결과보다 더 높다.

-       본 실험에서는 유도용액 3M, 0.18m/s 의 공급용액 속도, 2.4bar의 외부압력 조건에서 가장 높은 flux 결과를 기록하였음

 

4. Originality & Creativity

 

본 논문은 실험적 결과와 시뮬레이션 한 결과를 비교하여 분석하였으므로, 이 연구결과를 기초로 FO-RO 조합공정에 대한 연구를 확장시켜 나갈 수 있다.

 